Filtration Membrane Discs
Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (72)
- (9)
- (135)
- (9)
- (9)
- (4)
- (6)
- (168)
- (1)
- (2)
- (1)
- (2)
- (3)
- (22)
- (61)
- (21)
- (86)
- (3)
- (1)
- (1)
- (41)
- (14)
- (91)
- (3)
- (43)
- (5)
- (2)
- (1)
- (1)
- (22)
- (1)
- (1)
- (2)
- (3)
- (4)
- (4)
- (3)
- (11)
- (2)
- (41)
- (119)
- (49)
- (3)
- (20)
- (197)
- (1)
- (47)
- (9)
- (21)
- (8)
- (74)
- (10)
- (20)
- (42)
- (1)
- (15)
- (1)
- (6)
- (1)
- (6)
- (1)
- (11)
- (28)
- (1)
- (1)
- (50)
- (5)
- (1)
- (17)
- (1)
- (432)
- (144)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (238)
- (1)
- (1)
- (2)
- (8)
- (139)
- (1)
- (1)
- (45)
- (26)
- (33)
- (2)
- (3)
- (1)
- (14)
- (1)
- (2)
- (5)
- (1)
- (3)
- (10)
- (1)
- (15)
- (2)
- (29)
- (19)
- (1)
- (15)
- (14)
- (16)
- (1)
- (5)
- (1)
- (1)
Filtered Search Results
MilliporeSigma™ Express™ PLUS Membrane Filters
Plain white polyethersulfone Express™ PLUS Membrane Filters provide ultrafast filtration for a variety of applications.
Disposable | Reusable |
---|---|
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Material (Membrane) | PES |
Color | White |
Material | PES |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Provide ultrafast filtration of tissue culture media, additives, buffers and other aqueous solutions. This membrane is also used in many ready-to-use sterile filtration devices. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Type WCN Cellulose Nitrate Membranes
Recommended for majority of routine applications, this membrane is manufactured under strictly controlled conditions. Whatman™ Type WCN Cellulose Nitrate Membranes narrow pore size distribution for improved surface capture and analysis.
Color | White |
---|---|
Material | Cellulose Nitrate |
Autoclavable | Autoclavable |
Cytiva Whatman™ Nylon Membranes
Flexible and durable for easier handling. Cytiva Nylon Membranes are naturally hydrophilic, eliminating need for wetting agents and prewetting when filtering aqueous solutions.
Material | Nylon |
---|---|
Hydrophobicity | Hydrophilic |
Autoclavable | Autoclavable |
Material | MCE |
---|---|
For Use With (Application) | For all analytical, ultracleaning, and sterilizing applications at temperatures below 75°C (167°F) – except those involving esters, ether-alcohols, ketones, nitroparaffins or strong acids and bases. |
Autoclavable | Autoclavable |
Thickness (Metric) | 125 μm |
---|---|
Pore Size | 0.45 μm |
Bubble Point | 22 psi |
Flow Rate | >2.6 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | PVDF |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 5 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
Pore Size | 5 μm |
---|---|
Disposable | Reusable |
Material (Membrane) | Cellulose |
Color | White |
Material | MCE |
Sterility | Non-sterile |
Thickness (Metric) | 135 μm |
Bubble Point | ≥0.42 bar, air with water |
Flow Rate | 580 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Format | Disc |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Membrane Type | Plain |
Gas Flow Rate | 32 L/min./cm2 |
Thermo Scientific™ Nalgene™ Membrane and Prefilter Disks
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Carry out particulate and microbial analysis with these filter membranes. Available in various forms for water quality work, cold sterilization or sample clean up.
MilliporeSigma™ MF-Millipore™ Membrane Filter, 8 μm
Mixed cellulose esters (MCE) membrane, hydrophilic
Pore Size | 8 μm |
---|---|
Flow Rate | 620 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Color | White |
Material | MCE |
Hydrophobicity | Hydrophilic |
For Use With (Application) | For use in air monitoring; Fluid monitoring; Particle collection and analysis; QC of fluid holding tanks. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ Durapore™ Membrane Filters, 0.1 μm
Durapore™ Membrane Filters are recommended when maximum recovery is important.
Pore Size | 0.1 μm |
---|---|
Type | Filter Membranes |
Material (Membrane) | PVDF |
Color | White |
Material | PVDF |
Filter Type | Screen Filter |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm
MF-Millipore™ Membrane Filter are mixed cellulose esters (MCE) membrane, hydrophilic.
Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.45 μm |
Disposable | Reusable |
Flow Rate | 60 mL/min. x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
Material (Membrane) | Cellulose |
Material | MCE |
Filter Type | Membrane Filter |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman™ Nuclepore Hydrophilic Membrane
Nuclepore track-etched hydrophilic membranes with highly defined pore size cutoff in sub-micron range
Type | Nuclepore hydrophilic membrane |
---|---|
Material | Polycarbonate |
For Use With (Application) | Bioassays, Cell biology, Environmental analysis, Microscopy, Cytology, Parasitology, Certain air and oceanography analyses |
GVS Magna™ Nylon Membrane Filters
Plain white nylon membranes offer low extractables, high uniformity
Material | Nylon |
---|---|
Hydrophobicity | Hydrophilic |
For Use With (Application) | Permit use for aqueous filtration without wetting and organic solvent filtrations such as HPLC |
Autoclavable | Autoclavable |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.45 μm, Gridded
Mixed cellulose esters (MCE) membrane, hydrophilic
Thickness (Metric) | 150 μm |
---|---|
Pore Size | 0.45 μm |
Flow Rate | 60 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
No. per Case | 100Pack |
Quantity | 100/Pk. |
Material | MCE |
Hydrophobicity | Hydrophilic |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Membrane Type | Gridded |
Gas Flow Rate | 4 L/min/ cm2 |
Cytiva Whatman™ Anodisc™ Filter Membranes
Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.
Material | Aluminum Oxide |
---|
Pore Size | 0.45 μm |
---|---|
Bubble Point | 35.5 psi |
Flow Rate | 60 mL/min x cm2 |
Wettability | Hydrophilic |
Type | Filter Membranes |
No. per Case | 100Pack |
Quantity | 100/Pk. |
Material | Nylon |
Filter Type | Screen Filter |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Clarifying aqueous or organic solutions prior to HPLC analysis. |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |