Cellular Imaging
Cellular Imaging
Filtered Search Results
Thermo Scientific™ Pierce™ 16% Formaldehyde (w/v), Methanol-free
Vials of high-quality, methanol-free formaldehyde, a general IHC fixative and reversible amine-crosslinking agent for protein and nucleic acid samples.
Content And Storage | Store in original container protected from direct sunlight in a dry, cool and well-ventilated area. |
---|---|
Type | Formaldehyde |
Format | Liquid |
Reagent Type | Fixation Reagent |
Product Line | Pierce |
Invitrogen™ Countess™ 3 Automated Cell Counter
Experience rapid cell counting with the Countess 3 Automated Cell Counter. Equipped with advanced optics, automated focus and lighting, and AI-based image analysis software, the Countess 3 brightfield cell counter enables automated cell counting and measurement of cell viability.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Shipping Condition | Ambient |
---|---|
Electrical Requirements | 12 VDC, 3 A |
Dimensions | 9 x 9 x 5.5 in. (228.6 x 228.6 x 139.7 mm) |
Optics | 1 Channel (Brightfield) |
For Use With (Application) | Cell Counting and Viability Measurement |
Detection Method | Brightfield |
For Use With (Equipment) | EVOS Microscopes, Countess Chamber Slides, and Reusable Slide |
Voltage | 100/240 V |
Weight (English) | 8 lb. |
Certifications/Compliance | RoHS |
Camera | 5 MP |
Magnification | 2.5X |
Weight (Metric) | 3.6 kg |
Display | LCD (1280 x 800 pixels) |
Product Line | Countess |
Invitrogen™ Live Cell Imaging Solution
The Live Cell Imaging Solution from Molecular Probes™ is a physiological medium developed for live cell imaging applications that has universal utility in cell-based research—for live cell imaging, dye loading, and wash steps.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Agilent BioTek Lionheart FX Automated Microscope
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Lionheart FX automated microscope is a compact system for a broad range of imaging workflows. For Research Use Only. Not for use in diagnostic procedures.
Invitrogen™ EVOS™ M5000 Imaging System
The EVOS M5000 Imaging System is a fully integrated digital inverted benchtop system for four-color fluorescence, transmitted light, and color imaging.
Invitrogen™ EVOS™ XL Core Configured Cell Imager with Mechanical Stage
The EVOS XL Core Imaging System is a digital transmitted-light inverted imaging system for cell and tissue culture applications and routine cell maintenance.
Agilent BioTek Cytation 1 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
BioTek Cytation 1 cell imaging multi-mode reader combines fluorescence and high contrast brightfield imaging with conventional multi-mode detection. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20 in. |
Width (English) | 16.5 in. |
Shaking | Linear, Orbital, Double Orbital |
Light Source | Xenon Flash |
Width (Metric) | 41.9 cm |
Reading Options | Endpoint, kinetic, area scanning, plate mode inject/read process and well mode inject/read process |
Type | Cell Imaging Multi-Mode Microplate Reader |
Depth (Metric) | 50.8 cm |
Software | Gen5 Microplate Reader and Imager Software |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature Range (Metric) | Incubation to 45°C |
O2 Concentration Range | 0 to 19% |
CO2 Concentration Range | 0 to 20% |
Height (English) | 17.5 in. |
Resolution | 0.3 μm/pixel at 20X |
Plate Type | 6-well to 384-well plates |
Invitrogen™ FLoid™ Cell Imaging Station
Captures high-quality, three-color fluorescent cell images right at your benchtopx
Invitrogen™ EVOS™ M5000 Imaging System
The Invitrogen™ EVOS™ M5000 Cell Imaging System brings simple, automated microscopy within reach. All-in-one design includes high resolution fluorescence imaging, unique color illumination, a full suite of fluorescent filters, and intuitive software.
Agilent BioTek Cytation 7 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
BioTek Cytation 7 cell imaging multi-mode reader combines automated digital upright and inverted widefield microscopy with conventional multi-mode microplate reading. For Research Use Only. Not for use in diagnostic procedures.
Scan Speed | 96-wells: 11 s; 384-wells: 22 s |
---|---|
Shaking | Linear, Orbital, Double Orbital |
Light Source | Xenon Flash |
Wavelength | Luminescence 300 to 700 nm; Absorbance 230 to 999 nm, 1 nm increment |
Detection Method | Monochromator- based fluorescence intensity, luminescence and absorbance |
Reading Options | End point, kinetic, spectral scanning and well area scanning |
Sensitivity | Fluorescein 2.5 pM (0.25 fmol/well, 384-well plate) – top Fluorescein 4 pM (0.4 fmol/well, 384-well plate) – bottom; luminescence 20 amol ATP (flash) |
Type | Automated Microscope/Multi-Mode Microplate Reader |
No. of Dispensers | 2 Syringe Pumps |
Dispense Volume | 5 to 1000 μL, 1 μL increments |
Linearity | <1% from 0 to 3 OD |
Voltage | 100/240 V |
Bandwidth | 4 nm (230 to 285 nm), 8 nm (>285 nm) |
Frequency | 50/60 Hz |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Wavelength Selection | Quad monochromators (top/bottom) |
Temperature Range (Metric) | 4-Zone incubation to 45°C with Condensation Control (±0.5°C at 37°C) |
Resolution | 0.0001 OD |
Plate Type | Monochromator: 6- to 384-well plates; Imaging: 6- to 1536-well plates |
Agilent BioTek Cytation 5 Cell Imaging Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20.2 in. |
Width (English) | 16.4 in. |
Contrast Methods | Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast |
Shaking | Linear, Orbital, Double Orbital |
Wattage | 250 W max. |
Objectives | 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x |
Width (Metric) | 41.6 cm |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
Type | Cell Imaging Only Microplate Reader |
For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
Depth (Metric) | 51.4 cm |
Weight (English) | 80 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Camera | Sony CMOS, 16-bit Gray Scale, Standard or WFOV |
Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 36.3 kg |
Height (English) | 17.5 in. |
Plate Type | Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates |
Invitrogen™ EVOS™ XL Core Configured Cell Imager
The EVOS XL Core Imaging System is a digital transmitted-light inverted imaging system for cell and tissue culture applications and routine cell maintenance.
Agilent BioTek Cytation 5 Multi-Mode Only Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20.2 in. |
Width (English) | 16.4 in. |
Shaking | Linear, Orbital, Double Orbital |
Wattage | 250 W max. |
Absorbance Range | 230 to 999 nm, 1 nm increments |
Light Source | Xenon Flash; 100 mW 680 nm laser (Alpha Detection) |
Width (Metric) | 41.6 cm |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
Reading Options | End point, kinetic, spectral scanning and well area scanning |
Accuracy | Monochromator: ±2 nm; Dispenser: ±1 μL or 2% |
Type | Multi-Mode Only Microplate Reader |
No. of Dispensers | 2 Syringe Pumps |
Dispense Volume | 5 to 1000 μL, 1 μL increments |
For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
Depth (Metric) | 51.4 cm |
Weight (English) | 80 lb. |
Software | Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option) |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 36.3 kg |
Height (English) | 17.5 in. |
Corning™ Videodrop
Through the utilization of interferometry in conjunction with microscopy, the Corning™ Microdrop; senses, detects, characterizes, and tracks single nanoparticles in real time.
Agilent BioTek Cytation 5 Cell Imaging Multi-Mode Reader
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform. For Research Use Only. Not for use in diagnostic procedures.
Height (Metric) | 44.5 cm |
---|---|
Depth (English) | 20.2 in. |
Width (English) | 16.4 in. |
Contrast Methods | Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast |
Shaking | Linear, Orbital, Double Orbital |
Wattage | 250 W max. |
Objectives | 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x |
Absorbance Range | 230 to 999 nm, 1 nm increments |
Light Source | Xenon Flash; 100 mW 680 nm laser (Alpha Detection) |
Width (Metric) | 41.6 cm |
Dynamic Range | Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades |
Reading Options | End point, kinetic, spectral scanning and well area scanning |
Accuracy | Monochromator: ±2 nm; Dispenser: ±1 μL or 2% |
Type | Cell Imaging Multi-Mode Microplate Reader |
No. of Dispensers | 2 Syringe Pumps |
Dispense Volume | 5 to 1000 μL, 1 μL increments |
For Use With (Equipment) | BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible |
Depth (Metric) | 51.4 cm |
Weight (English) | 80 lb. |
Certifications/Compliance | CE and TUV marked. RoHS compliant. |
Camera | Sony CMOS, 16-bit Gray Scale, Standard or WFOV |
Temperature Range (Metric) | 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C) |
CO2 Concentration Range | 0 to 20% |
Weight (Metric) | 36.3 kg |
Height (English) | 17.5 in. |